Skip to Content
Representative photo. Please check item description for details.

KROHNE UFC 400-v2 Ultrasonic Flow Converter

https://www.branom.com/web/image/product.template/554330/image_1920?unique=c26756c
(0 review)

  • Type
  • Power Supply
  • Ex-Approval
  • Cable Connection
  • Custody Transfer
  • Process Diagnostics
  • Converter Housing
  • Communication
  • First IO Module
  • Second IO Module
  • Sensor
  • Tagplate

This combination does not exist.

Specifications

Type [VN3545] UFC 400 C, Compact Mount Housing, [VN354K] UFC 400 F, Field Mount Housing
Power Supply [1] 12-24 VDC, [4] 19-29 VDC/AC, [A] 85-250 VAC, 50/60 Hz
Ex-Approval [0] without - non Ex, [4] CSAus Class 1 DIV 1 (US), [4] QPSus Class 1 DIV 1 (US), [B] cCSAus Class 1 DIV 1 (US & Canada), [B] cQPSus Class 1 DIV 1 (US & Canada), [1] ATEX Ex Zone 1 (Terminal Compartment "d"), [2] ATEX Ex Zone 1 (Terminal Compartment "e"), [F] IECEx Zone 1 (Terminal Compartment "d"), [G] IECEx Zone 1 (Terminal Compartment "e")
Cable Connection [46] 3x ½" NPT, [66] 3x M20 x 1.5
Custody Transfer [0] without, [K] Water - Hot, acc. MI-004 EU
Process Diagnostics [0] Standard, [T] SIL PIU
Converter Housing [10] Die-Cast Aluminum, [20] Stainless Steel 1.4408|316 - Compact, [20] Stainless Steel 1.4408|316 - Field, [30] Die-Cast Aluminum, Custody Transfer: Sealed, [40] Stainless Steel 1.4408|316, Custody Transfer: Sealed - Compact, [40] Stainless Steel 1.4408|316, Custody Transfer: Sealed - Field
Communication [1] Basic IO (4-20 mA / HART + Pulse / Frequency + Status + Control), [2] Ex-i IO: Current Output Active + Pulse Output / Control Input Passive, [3] Ex-i IO: Current Output Passive + Pulse Output / Control Input Passive, [4] Current Output Active + Pulse Output Active, [6] Current Output Active + Pulse Output Passive, [7] Current Output Active + Pulse Output Namur, [8] Current Output Passive + Pulse Output Active, [B] Current Output Passive + Pulse Output Passive, [C] Current Output Passive + Pulse Output Namur, [D] Fieldbus IO: Profibus PA, [E] Fieldbus IO: Foundation Fieldbus, [F] Fieldbus IO: Profibus DP, [G] IO: RS485 Modbus
First IO Module [0] No Module Possible, [8] Without IO Module, [1] Ex-i IO: Current Output Active + Pulse Output / Control Input Passive, [2] Ex-i IO: Current Output Passive + Pulse Output / Control Input Passive, [A] Current Output - Active, [B] Current Output - Passive, [C] Pulse Output - Active / High Current, [E] Pulse Output - Passive / High Current, [F] Pulse Output - Passive / Namur, [G] Control Input - Active / High Current, [H] Control Input - Active / Namur, [K] Control Input - Passive / High Current
Second IO Module [0] No Module Possible, [8] Without IO Module, [A] Current Output - Active, [B] Current Output - Passive, [C] Pulse Output - Active / High Current, [E] Pulse Output - Passive / High Current, [F] Pulse Output - Passive / Namur, [G] Control Input - Active / High Current, [H] Control Input - Active / Namur, [K] Control Input - Passive / High Current
Sensor [0] Optisonic 3000, [2] Optisonic 4000 HT, [3] Optisonic 4000 HP
Tagplate [03] without - Tag Info on Foiled Nameplate, [23] 316|1.4401 tagplate ( 120 x 46 mm ), [33] 316|1.4401 tagplate ( 67 x 25 mm )