Signal converter for electromagnetic flowmeters

  • Extended accuracy option
  • Diagnostics of device and application 

Highlights

  • For operation with a wide range of OPTIFLUX and WATERFLUX flow sensors
  • For flow sensors over a diameter range from DN2.5 up to DN1200
  • Housing in aluminium with a polyester topcoat or in stainless steel (option)
  • Tropicalized electronics to protect it from humidity (option)
  • Available outputs: 4...20 mA current output, pulse/frequency output and status output/limit switch
  • Control input option
  • HART® as standard
  • Power supply via 100…230 VAC (standard) or 24 VDC or 24 VAC/DC (optional)
  • Clearly readable values due to angle of the signal converter housing which prevents dirt and dust on the display
  • Extended calibration option for higher measuring accuracy down to 0.2% of the measuring value
  • Excellent price/performance ratio

  • Type
  • Power Supply
  • Hazardous Area Approvals
  • Cable Connection
  • Process Diagnostics
  • Converter Housing
  • Outputs
  • Tag Plate

This combination does not exist.


Product Datasheets

Datasheet 1

Signal converter for electromagnetic flowmeters

  • Extended accuracy option
  • Diagnostics of device and application 

Highlights

  • For operation with a wide range of OPTIFLUX and WATERFLUX flow sensors
  • For flow sensors over a diameter range from DN2.5 up to DN1200
  • Housing in aluminium with a polyester topcoat or in stainless steel (option)
  • Tropicalized electronics to protect it from humidity (option)
  • Available outputs: 4...20 mA current output, pulse/frequency output and status output/limit switch
  • Control input option
  • HART® as standard
  • Power supply via 100…230 VAC (standard) or 24 VDC or 24 VAC/DC (optional)
  • Clearly readable values due to angle of the signal converter housing which prevents dirt and dust on the display
  • Extended calibration option for higher measuring accuracy down to 0.2% of the measuring value
  • Excellent price/performance ratio

Specifications

Type [VN3144] C-Compact (0°) for Vertical Pipes, [VN3146] C-Compact (45°) for Horizontal Pipes, [VN314N] W-Wall Mount
Power Supply [A] 85-250 VAC, [1] 12-24 VDC, [4] 19-29 V DC/AC
Hazardous Area Approvals [0] None / General Purpose, [5] cFMus Class 1 DIV 2, [A] CSA Ordinary Location * Required for Canada
Cable Connection [460] 1/2" NPT, [660] M20 x 1.5
Process Diagnostics [D] Empty Pipe Detection, [C] Tropicalized electronics for General Purpose only, [0] Standard
Converter Housing [10] Die-Cast Aluminum (Polyurethane Coated), [20] 316 Stainless Steel
Tag Plate [03] Without, [23] 316SS (120x46mm), [33] 316SS (67x25mm)
Outputs [1000] 4-20 mA/HART + pulse/frequency + status