Skip to Content
Representative photo. Please check item description for details.

KROHNE GFC 300 Ultrasonic Flow Converter

https://www.branom.com/web/image/product.template/554189/image_1920?unique=c26756c
(0 review)

  • Type
  • Power Supply
  • Ex-Approval
  • Cable Connection
  • Custody Transfer
  • Process Diagnostics
  • Converter Housing
  • Communication
  • First IO Module
  • Second IO Module
  • Tagplate

This combination does not exist.

Specifications

Type [VN3644] GFC 300 C, Compact/Integral Mount Converter, [VN364H] GFC 300 F, Field Mount Converter
Power Supply [1] 12-24 VDC, [4] 19-29 V DC/AC, [A] 85-250 VAC, 50/60 Hz
Ex-Approval [0] without - non Ex, [1] ATEX Ex Zone 1 (Terminal Compartment "d"), [2] ATEX Ex Zone 1 (Terminal Compartment "e"), [4] Class 1 DIV 1 (US), [5] Class 1 DIV 2 (US), [B] Class 1 DIV 1 (Canada), [C] Class 1 DIV 2 (Canada), [F] IECEx Zone 1 (Terminal Compartment "d"), [G] IECEx Zone 1 (Terminal Compartment "e")
Cable Connection [46] 3x 1/2" NPT, [66] 3x M20 x 1.5
Process Diagnostics [0] Standard, [P] Biogas, [A] P&T Current Input Correction - Normal, [B] P&T Current Input Correction - Old Normal, [D] Steamflow - Superheated Steam, [E] P&T Current Input Correction Correction - IUPAC, [F] P&T Current Input Correction - OPEC & AGA, [G] P&T Manual Input Correction - Normal, [H] P&T Manual Input Correction - Old Normal, [K] P&T Manual Input Correction Correction - IUPAC, [L] P&T Manual Input Correction - OPEC & AGA, [M] P&T Manual Input Correction - GOST, [N] P&T Manual Input Correction - GB/T, [V] P&T Correction - GOST, [W] P&T Correction - GB/T
Converter Housing [10] Aluminum, [20] Stainless Steel 316|1.4408 - Compact Mount Housing, [20] Stainless Steel 316|1.4408 - Field Mount Housing
Communication [1] Basic IO (4-20 mA / HART + pulse / frequency + status + control), [2] Ex-i IO: Current Output Active + Pulse Output / Control Input Passive, [3] Ex-i IO: Current Output Passive + Pulse Output / Control Input Passive, [4] Current Output Active + Pulse Output Active, [6] Current Output Active + Pulse Output Passive, [7] Current Output Active + Pulse Output Namur, [8] Current Output Passive + Pulse Output Active, [B] Current Output Passive + Pulse Output Passive, [C] Current Output Passive + Pulse Output Namur, [E] Fieldbus IO: Foundation Fieldbus, [G] IO: RS485 Modbus
First IO Module [0] No Module Possible, [8] Without IO Module, [1] Ex-i IO: Current Output Active + Pulse Output / Control Input Passive, [2] Ex-i IO: Current Output Passive + Pulse Output / Control Input Passive, [5] Ex-i IO: 2x Current Input Active, [A] Current Output - Active, [B] Current Output - Passive, [C] Pulse Output - Active / High Current, [E] Pulse Output - Passive / High Current, [F] Pulse Output - Passive / Namur, [G] Control Input - Active / High Current, [H] Control Input - Active / Namur, [K] Control Input - Passive / High Current, [P] Current Input - Active, [R] Current Input - Passive
Second IO Module [0] No Module Possible, [8] Without IO Module, [A] Current Output - Active, [B] Current Output - Passive, [C] Pulse Output - Active / High Current, [E] Pulse Output - Passive / High Current, [F] Pulse Output - Passive / Namur, [G] Control Input - Active / High Current, [H] Control Input - Active / Namur, [K] Control Input - Passive / High Current, [P] Current Input - Active, [R] Current Input - Passive
Tagplate [003] without, [023] 316SS (120x46mm), [033] 316SS (67x25mm)
Custody Transfer [0] without