Skip to Content
Representative photo. Please check item description for details.

VACON 100 FLOW, 125 HP / 90 KW, 380-500 VAC, 3 Phase, IP54, 170 Amp, VACON0100-3L-0170-5-FLOW-R02+SEBJ+IP54

https://www.branom.com/web/image/product.template/196537/image_1920?unique=c26756c
(0 review)

  • Product Series: (0100) Vacon 100 series
  • Segment: (-FLOW) VACON 100 FLOW
  • Installation options: (-DM) DM Drive Module
  • Phase: (-3L) 3 Phase AC Input
  • Mains voltage: (-5) 380-500 Vac
  • Current rating: (-0170) 170 Amp
  • Enclosure: (+IP00) IP00
  • EMC emission limit category: (+EMC4) EMC C4 System Component
  • Control panel: (+HMGR) Graphical Keypad MK01
  • Brake chopper: (+DBNO) No dynamic braking device
  • B-Slot Option Board: (+SBF3) F3,3 Relay board
  • C- Slot Option Board: (+SC00) No board
  • D-Slot Option Board: (+SD00) No board
  • E-Slot Option Board: (+SE00) No board
  • Real time clock option: (+SRNO) No Battery for real time clock
  • Common mode filter (for DM): (+P000) No Option
  • DUT filter (for DM): (+P000) No Option
  • Cable entry: (+QGLC) Inch conduit plate
  • Additional Equipment B: (+Q000) No option for Qxxx_B (+Q000)
  • Additonal Equipment C: (+Q000) No additonal option for Qxxx_C
  • Motor parameter default freq: (+LS60) 60 Hz def motor freq settings
  • Firmware Language Pack: (+FL03) UK, ES, FR, IT, NL, PT lang
  • Documentation level: (+DPAP) Paper Manuals
  • Document language preference: (+DLUK) English
  • Internal FB selection: (+FBIE) IndEth (ProfinetIO,EthernetIP)
  • Auxilary power supply: (+C000) no option (+C000)
  • DC power supply for aux device: (+C000) no option (+C000)
  • AC socket for aux devices: (+C000) no option (+C000)
  • Common mode filter (for ED): (+P000) no option
  • DU/DT, Sine filter (for ED): (+P000) no option
  • Door Equipments: (+C000) no option (+C000)
  • Cabinet heater: (+C000) no option (+C000)
  • Cabinet light: (+C000) no option (+C000)
  • Motor heater control: (+C000) no option (+C000)
  • Emergency stop options: (+C000) no option (+C000)
  • Insulation fault sensor: (+C000) no option (+C000)
  • Cabling from top: (+C000) no option (+C000)
  • Back channel cooling: (+C000) no option (+C000)
  • Cabinet Plinth: (+C000) no option (+C000)
  • Marine construction: (+E000) no option
  • UL approval: (+GAUL) UL Approval (+GAUL)
  • CE approval: (+GACE) CE Approval (+GACE)
  • RCM Approval: (+GACT) (+GACT) RCM Approval N16307
  • KC approval: (+GAKC) KC Approval
  • Motor Power Low Overload [kW]: 90
  • Continuous Current (NO) [A]: 170
  • Dimensions WxHxD [mm] net: 290 X 794 X 343
  • Calculated Net Weight [kg]: 50
  • Frame Size: MR08

13,985.36 13985.36 USD 13,985.36

13,985.36

Not Available For Sale

  • AC Drive: Brand
  • AC Drive: Series
  • AC Drive: Power Rating
  • AC Drive: Output
  • AC Drive: Voltage
  • AC Drive: IP Rating

This combination does not exist.

  • Product Series: (0100) Vacon 100 series
  • Segment: (-FLOW) VACON 100 FLOW
  • Installation options: (-DM) DM Drive Module
  • Phase: (-3L) 3 Phase AC Input
  • Mains voltage: (-5) 380-500 Vac
  • Current rating: (-0170) 170 Amp
  • Enclosure: (+IP00) IP00
  • EMC emission limit category: (+EMC4) EMC C4 System Component
  • Control panel: (+HMGR) Graphical Keypad MK01
  • Brake chopper: (+DBNO) No dynamic braking device
  • B-Slot Option Board: (+SBF3) F3,3 Relay board
  • C- Slot Option Board: (+SC00) No board
  • D-Slot Option Board: (+SD00) No board
  • E-Slot Option Board: (+SE00) No board
  • Real time clock option: (+SRNO) No Battery for real time clock
  • Common mode filter (for DM): (+P000) No Option
  • DUT filter (for DM): (+P000) No Option
  • Cable entry: (+QGLC) Inch conduit plate
  • Additional Equipment B: (+Q000) No option for Qxxx_B (+Q000)
  • Additonal Equipment C: (+Q000) No additonal option for Qxxx_C
  • Motor parameter default freq: (+LS60) 60 Hz def motor freq settings
  • Firmware Language Pack: (+FL03) UK, ES, FR, IT, NL, PT lang
  • Documentation level: (+DPAP) Paper Manuals
  • Document language preference: (+DLUK) English
  • Internal FB selection: (+FBIE) IndEth (ProfinetIO,EthernetIP)
  • Auxilary power supply: (+C000) no option (+C000)
  • DC power supply for aux device: (+C000) no option (+C000)
  • AC socket for aux devices: (+C000) no option (+C000)
  • Common mode filter (for ED): (+P000) no option
  • DU/DT, Sine filter (for ED): (+P000) no option
  • Door Equipments: (+C000) no option (+C000)
  • Cabinet heater: (+C000) no option (+C000)
  • Cabinet light: (+C000) no option (+C000)
  • Motor heater control: (+C000) no option (+C000)
  • Emergency stop options: (+C000) no option (+C000)
  • Insulation fault sensor: (+C000) no option (+C000)
  • Cabling from top: (+C000) no option (+C000)
  • Back channel cooling: (+C000) no option (+C000)
  • Cabinet Plinth: (+C000) no option (+C000)
  • Marine construction: (+E000) no option
  • UL approval: (+GAUL) UL Approval (+GAUL)
  • CE approval: (+GACE) CE Approval (+GACE)
  • RCM Approval: (+GACT) (+GACT) RCM Approval N16307
  • KC approval: (+GAKC) KC Approval
  • Motor Power Low Overload [kW]: 90
  • Continuous Current (NO) [A]: 170
  • Dimensions WxHxD [mm] net: 290 X 794 X 343
  • Calculated Net Weight [kg]: 50
  • Frame Size: MR08

Specifications

AC Drive: Brand Danfoss
AC Drive: Series VACON 100
AC Drive: Power Rating 3 Phase
AC Drive: Output 125 HP / 90 KW
AC Drive: Voltage 380-500 VAC
AC Drive: IP Rating IP54